Logger Script
본문바로가기

제품소개

Best Global Partnership NEMO TECH CO.,LTD

제품 품목별

  • homeHOME
  • >
  • 제품소개
  • >
  • 제품 품목별

Easy, Wireless Collection of a Variety of Data Types, including Voltage Input and Thermocouple Types

제조사
HIOKI
제품명
WIRELESS VOLTAGE/TEMP LOGGER LR8515
제품번호
LR8515

견적문의 카달로그

PRODUCT INFO. 제품상세정보

• A single device to measure everything from the minute voltages of pyranometers
   or heat flow sensors to battery voltage to temperature

• Compact, two-channel model fits where other devices don’t

• Download measurement data to a tablet or computer with Bluetooth® wireless technology

   or capture in real time with the LR8410

• Three-way power (AC adapter, AA alkaline batteries, or external 5 to 13.5 V power supply)

• Store 500,000 data points per channel

PRODUCT INFO. 제품상세정보

Basic specifications (Accuracy guaranteed for 1 year, Duration of the post-adjustment accuracy guarantee for 1 year)


Functionality

[Used as standalone product (Data collected manually) ]
Windows PC or Windows tablet (CD-R with software included)
Android smartphone or Android tablet terminal
(Software can be downloaded free of charge from Google Play.)
*Communication range varies with the performance of the computer or tablet (up to a line-of-sight distance of roughly 30 m)
[Used as logging module (Real-time measurement) ]
Device can be used as an LR8410 logging module to record and display data in real time and to control up to 7 units, Communication distance: 30 m

Number of channels

2 ch (isolated; select voltage of thermocouple for each channel), Input terminals: M3 screw type terminal block

Measurement items

Voltage/ Thermocouple (K, T)

Maximum input voltage

±50 V DC, Max. inter-channel voltage 70 V DC

Measurement range

[Voltage] ±50 mV to ±50 V , Max. resolution 0.01 mV
[Thermocouple] -200 ˚C to 999.9 ˚C, Thermocouples (K, T), Max. resolution 0.1 ˚C

Measurement accuracy

[Voltage] ±0.05 mV (50 mV range)
[Thermocouple] ±0.8 ˚C (Thermocouple K -100 ˚C to 999.9 ˚C)
*Reference junction compensation: Switchable between internal and external
*Reference junction compensation accuracy: ±0.5 ˚C
(When using internal compensation, add to thermocouple measurement accuracy.)
*Temperature characteristics: Add (measurement accuracy × 0.1) / ˚C to measurement accuracy.

Display items

Measurement value, date, time, number of recorded data, maximum value, minimum value, and average value

Functions

Alarm, Scaling, Recording operation hold function, Erroneous operation prevention, Comment recording function, Power saving function, Authentication function, Free run

Recording

[Capacity] 500,000 data items for each channel [Mode] Instantaneous value [Interval] 0.1 to 30 sec, 1 to 60 min, 16 selections

Power source

AC Adapter Z2003 (AC100 V to 240 V, 50 Hz/60 Hz), AA alkaline batteries (LR6) ×2, External power DC5 V to 13.5 V (can also be supplied from USB bus power, with a conversion cable)

Continuous operating time ([Capacity] 500,000 data items for each channel) (23˚C)

2.5 months (Recording interval of 1 min, Bluetooth® OFF), 7 days (Recording interval of 1 sec, Bluetooth® ON), 2 days (Recording interval of 0.1 sec, during real-time measurement with the LR8410)

Dimensions and mass

85 mm (3.35 in) W × 75 mm (2.95 in) H × 38 mm (1.50 in) D, 126 g (4.4 oz) (Not including the battery)

Accessories

CD-R ×1 (Instruction Manual, Logger Utility, Wireless Logger Collector), Measurement Guide ×1, Caution for Using Radio Waves × 1, AA alkaline batteries (LR6) ×2


Countries and regions where wireless operation is currently supported (LR8512, LR8513, LR8514, LR8515, LR8520)


Wireless certification

Japan, Unaited States, Canada, European Union, Norway, Switzerland, Turky, Singapore, Australia, New Zealand, China, Taiwan, Thailand, and Chile

Exempt from the wireless regulations

Russia, Viet Nam, India, Hong Kong, Macao, Colombia, and Pakistan


PRODUCT INFO. 제품상세정보


8515_o.jpg


목록